Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Bottom Distribution Piping
Heat removal solutions designed to meet the diverse requirements of the data center and surrounding environment.
Includes: Installation guide
ACFD12-BFeatures
Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Bottom Distribution Piping
-
Coolant balancing
Provides a central point for fluid balancing.
-
Front service access
The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
-
Isolated cooling circuit
A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak.
-
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
InRow Chilled Water CoolingFeatures & Benefits
Manageability
-
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
-
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
-
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Agility
-
Casters
Provides flexibility to move the unit to wherever cooling is required.
-
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
-
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Serviceability
Availability
-
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
-
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
-
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
-
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
-
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Total Cost of Ownership
-
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
-
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Physical
-
Maximum Height
1991mm , 199.1cm
-
Maximum Width
1070mm , 107.0cm
-
Maximum Depth
750mm , 75.0cm
-
Net Weight
269.56kg
-
Shipping weight
314.56kg
-
Shipping Height
2159mm , 215.9cm
-
Shipping Width
1219mm , 121.9cm
-
Shipping Depth
889mm , 88.9cm
-
Color
Black
-
Units per Pallet
1.0
Conformance
-
Approvals
MEA
-
Standard warranty
1 year (parts only)