InRow RP Chilled Water 380-415V 50 Hz
Includes: Installation Guide , Operations and Maintenance Manual
ACRP502Features
InRow RP Chilled Water 380-415V 50 Hz
-
Electric Reheat
Prevents overcooling during dehumidification.
-
Humidifier
Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.
InRow Chilled Water CoolingFeatures & Benefits
Manageability
-
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
-
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
-
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Agility
-
Casters
Provides flexibility to move the unit to wherever cooling is required.
-
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
-
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Serviceability
Availability
-
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
-
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
-
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
-
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
-
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Total Cost of Ownership
-
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
-
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Input
-
Nominal Input Voltage
400V 3PH
-
Input frequency
50 Hz +/- 3 Hz
-
Input Connections
Hard Wire 4-wire (3PH + G)
-
Number of Power Cords
2
-
Input Power
15000.0Watts
Communications & Management
-
Control panel
Multi-function LCD status and control console
-
Audible Alarm
Audible and visible alarms prioritized by severity
Physical
-
Maximum Height
1991mm , 199.1cm
-
Maximum Width
600mm , 60.0cm
-
Maximum Depth
1070mm , 107.0cm
-
Rack Height
42U
-
Net Weight
352.73kg
-
Shipping weight
463.18kg
-
Shipping Height
2166mm , 216.6cm
-
Shipping Width
850mm , 85.0cm
-
Shipping Depth
1137mm , 113.7cm
-
Color
Black
-
Units per Pallet
1.0
Conformance
-
Approvals
cUL Listed, FCC Part 15 Class A, GOST, Industry Canada
-
Standard warranty
1 year (parts only), 1 year on-site repair or replace with factory authorized Start-Up
Sustainable Offer Status