Basic Rack PDU
Rack PDU, Basic, Zero U, 10A,230V, (15)C13
APC Basic Rack PDU, Input: 200V, 208V, 230V, Input Connections: IEC-320 C14, Cord Length:6.5 feet ( 1.98 meters ), Output: 208V, 230V, Output Connections: IEC 320 C13
Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit
Toolless Rack Mounting Capabilities
Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
Vertical Mounting Capabilities
Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.
Basic Rack PDU Features & Benefits
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Low Cost Power Distribution
Nominal Output Voltage
208V, 230V
Maximum Total Current Draw per Phase
10A
Output Connections
(15) IEC 320 C13
|
|
Nominal Input Voltage
200V, 208V, 230V
Cord Length
6.5 feet (1.98 meters)
Acceptable Input Voltage
200-240 VAC
Maximum Input Current per phase
10A
Net Weight
4.40 lbs. (2.00 kg)
Maximum Height
24.00 inches (610 mm)
Maximum Width
1.75 inches (44 mm)
Maximum Depth
1.75 inches (44 mm)
Shipping Weight
6.00 lbs. (2.73 kg)
Shipping Height
25.50 inches (648 mm)
Shipping Width
7.00 inches (178 mm)
Shipping Depth
6.00 inches (152 mm)
Operating Environment
32 - 113 °F (0 - 45 °C)
Operating Relative Humidity
0 - 95%
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
-13 - 149 °F (-25 - 65 °C)
Storage Relative Humidity
0 - 95%
Storage Elevation
0-50000 feet (0-15000 meters)
Regulatory Approvals
cUL Listed, CE, GOST, Queensland Australia, UL Listed, VDE
Standard Warranty
2 years repair or replace
REACH
REACH: Contains No SVHCs
PEP
Available in Documentation tab
EOLI
Available in Documentation tab
Battery Directive
Compliant
Battery Notes
Contains Lithium Coin Cell
Other Environmental Compliance
China RoHS