APC Smart-UPS VT Empty Frame for Transformer 10-40kVA 400V Floormount
Empty transformer cabinet for use with third party transformers.
Includes: Installation guide , User Manual
Smart-UPS VT Features & Benefits
Availability
-
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
-
Scalable runtime
Allows additional run time to be quickly added as needed.
-
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
-
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
-
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
Serviceability
-
Battery replacement without tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
-
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.
-
Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Manageability
-
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
-
Network manageable
Provides remote power management of the UPS over the network.
-
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
-
LED status indicators
Quickly understand unit and power status with visual indicators.
-
SmartSlot
Customize UPS capabilities with management cards.
-
Audible alarms
Provides notification of changing utility power and UPS power conditions
-
Programmable frequency
Ensures compatibility with different input frequencies.
Total Cost of Ownership
-
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
-
Manual maintenance bypass
Reduces installation costs by eliminating the need for an external mechanical bypass.
-
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
-
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Marketing Features
-
Manual maintenance bypass
Reduces installation costs by eliminating the need for an external mechanical bypass.
-
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
-
Network manageable
Provides remote power management of the UPS over the network.
-
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
-
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
-
Scalable runtime
Allows additional run time to be quickly added as needed.
Protection
-
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
-
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
Cold-start capable
Provides temporary battery power when the utility power is out.
Output
-
Nominal Output Voltage
400V 3PH
Input
-
Nominal Input Voltage
400V 3PH
-
Input frequency
50 Hz
Physical
-
Maximum Height
1487mm , 148.7CM
-
Maximum Width
523mm , 52.3CM
-
Maximum Depth
837mm , 83.7CM
-
Net Weight
147.0KG
-
Shipping weight
181.0KG
-
Shipping Height
1663mm , 166.37CM
-
Shipping Width
723mm , 72.39CM
-
Shipping Depth
1104mm , 110.49CM
Environmental
Conformance
-
Approvals
EN 50091-2, EN/IEC 62040-3, EN/IEC 62040-1-1
-
Standard warranty
1 year repair or replace